 <?xml-stylesheet type="text/css" href="https://suivet.it/Data/style/rss1.css" ?> <?xml-stylesheet type="text/xsl" href="https://suivet.it/Data/style/rss1.xsl" ?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:itunes="http://www.itunes.com/dtds/podcast-1.0.dtd">
  <channel>
    <title>I trucchi in allevamento - Ultimi articoli inseriti</title>
    <link>https://suivet.it/trucchi-in-allevamento.aspx</link>
    <description />
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>mojoPortal Blog Module</generator>
    <language>it-IT</language>
    <ttl>120</ttl>
    <atom:link href="https://suivet.it/Blog/RSS.aspx?p=8~15~10" rel="self" type="application/rss+xml" />
    <itunes:owner />
    <itunes:explicit>no</itunes:explicit>
    <item>
      <title>Con i tubi riscaldati…stanno al caldo gli svezzati!</title>
      <description><![CDATA[<table cellspacing="1" cellpadding="1" width="100%">
    <tbody>
        <tr>
            <td colspan="5" style="text-align: justify">Il riscaldamento: mille opinioni a confronto! <br />
            Potrebbe essere il titolo di un lungo articolo su come creare un ambiente termicamente idoneo per i suini, soprattutto nella fase di svezzamento (il vero punto debole della “carriera suina”), ma non sono la persona idonea alla stesura. In effetti, sono talmente tanti e vari (ed ugualmente validi) i modi e le attrezzature proposti dal mercato, che orientarsi all’interno di essi è, a dir poco, scoraggiante. La scheda presentata in questo numero, è un classico esempio di come un allevatore ha concretizzato (in maniera personalizzata ed autonoma)&#160; i concetti di: riscaldamento localizzato, risparmio energetico e realizzazione pratica all’interno di una struttura preesistente.</td>
        </tr>
        <tr>
            <td><a target="_blank" href="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_03.JPG"><img alt="tubi riscaldati" width="100" height="75" src="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_03.JPG" /></a></td>
            <td><a target="_blank" href="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_01.JPG"><img alt="tubi riscaldati" width="100" height="75" src="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_01.JPG" /></a></td>
            <td rowspan="3" colspan="3" style="text-align: justify">&#160;Partendo dal concetto di localizzare la fonte calorica, ha pensato di realizzare una griglia in tubi di acciaio (una specie di radiatore ad elementi&#160; allargati) in cui far scorrere l’acqua calda, appoggiato e fissato sul&#160; pavimento del box svezzamento (prendendo l’idea dagli impianti a pavimento delle abitazioni).Il dimensionamento della griglia è stato effettuato in funzione della dimensione del box, del numero di capi allevati e dell’estensione dell’area di riposo, cercando di prevedere la possibilità di riscaldamento per tutti i capi presenti in posizione di riposo.</td>
        </tr>
        <tr>
            <td><a target="_blank" href="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_02.JPG"><img alt="tubi riscaldati" width="100" height="125" src="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_02.JPG" /></a></td>
            <td><a target="_blank" href="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_04.JPG"><img alt="tubi riscaldati" width="100" height="125" src="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_04.JPG" /></a></td>
        </tr>
        <tr>
            <td><a target="_blank" href="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_05.JPG"><img alt="tubi riscaldati" width="60" height="75" src="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_05.JPG" /></a></td>
            <td><a target="_blank" href="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_07.JPG"><img alt="tubi riscaldati" width="100" height="75" src="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_07.JPG" /></a></td>
        </tr>
        <tr>
            <td colspan="2" style="text-align: justify">L’idraulico ha poi installato un caldaia a gas per il riscaldamento dell’acqua e le opportune tubature di collegamento ai vari elementi dei vari locali, con l’impiego di un miscelatore per la regolazione della temperatura dell’acqua circolante.</td>
            <td colspan="2"><a target="_blank" href="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_06.JPG"><img alt="tubi riscaldati" width="100" height="75" src="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_06.JPG" /></a></td>
            <td><a target="_blank" href="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_08.JPG"><img alt="tubi riscaldati" width="100" height="125" src="https://suivet.it/Data/Sites/1/media/trucchi/TubiCaldi/Tubi_caldi_08.JPG" /></a></td>
        </tr>
        <tr>
            <td colspan="5">Non sarà un sistema apprezzabile esteticamente,&#160;&#160; ma ai maiali l’estetica… non interessa.<br />
            L’importante, per l’allevatore è che funzioni e… che costi poco!</td>
        </tr>
    </tbody>
</table>
<p>&#160;</p><br /><a href='https://suivet.it/con-i-tubi-riscaldati…stanno-al-caldo-gli-svezzati.aspx'>Dott. Francesco Tonon</a><div class='fblikebutton'><iframe src='http://www.facebook.com/plugins/like.php?href=https%3a%2f%2fsuivet.it%2fcon-i-tubi-riscaldati%e2%80%a6stanno-al-caldo-gli-svezzati.aspx&amp;layout=standard&amp;show_faces=false&amp;width=450&amp;height=35&amp;action=like&amp;colorscheme=light' scrolling='no' frameborder='0' allowTransparency='true' style='border:none; overflow:hidden;width:450px; height:35px;'></iframe></div>]]></description>
      <link>https://suivet.it/con-i-tubi-riscaldati…stanno-al-caldo-gli-svezzati.aspx</link>
      <author>tonon@suivet.it (Dott. Francesco Tonon)</author>
      <comments>https://suivet.it/con-i-tubi-riscaldati…stanno-al-caldo-gli-svezzati.aspx</comments>
      <guid isPermaLink="true">https://suivet.it/con-i-tubi-riscaldati…stanno-al-caldo-gli-svezzati.aspx</guid>
      <pubDate>Fri, 23 Dec 2011 20:54:00 GMT</pubDate>
    </item>
  </channel>
</rss>